Before issuing vSEC:CMS software onto a new Gemalto IDBridge K3000 device, the device needs to be prepared using a software tool from Gemalto called the Toolbox (aka the Gemalto SG Core Toolbox). This document describes step-by-step, in detail how this is done. Should you still have any problem in preparing the IDBridge K3000, please contact Versatile Security:

http://versatilesecurity.com/versatilesecurity-contact.php

Step 0: Insert Device and Start the Toolbox

  1. Make sure that an Internet connection is available.

  2. Insert Device and wait for Windows update to install all drivers.

  3. Start the Toolbox.

Step 1: Set Credentials

From the Token Administration menu select Credentials.

NOTE: The following steps (1A-E) must be followed exactly as described, the order of the steps is extra important! If result is not exactly as described in this document, stop and contact Versatile Security right away.

Step 1A: Container 0F

  1. Select Container 0F and hit the Change Credential button.

  2. Validate that the Authentication Credential is set to: GENERIC PRODUCT KEY SET DETECTED

  3. Validate that the Old Credential is set to: GENERIC PRODUCT KEY SET DETECTED

  4. In the field New credential value, set: 1111111111111111111111111111111111111111111111111111111111111111 (64 repetitions of the digit 1)

  5. Hit the Apply button.

  6. Confirm the operation by hitting the OK button.

  7. Validate that the operation was successful and hit the OK button.

Step 1B: Container 09

  1. Select Container 09 and hit the Change Credential button.

  2. Validate that the Authentication Credential is set to: GENERIC PRODUCT KEY SET DETECTED

  3. Validate that the Old Credential is set to: GENERIC PRODUCT KEY SET DETECTED

  4. In the field New credential value, set: 1111111111111111111111111111111111111111111111111111111111111111 (64 repetitions of the digit 1)

  5. Hit the Apply button.

  6. Confirm the operation by hitting the OK button.

  7. Validate that the operation was successful and hit the OK button.

Step 1C: Container 08

  1. Select Container 08 and hit the Change Credential button.

  2. Validate that the Authentication Credential is set to: GENERIC PRODUCT KEY SET DETECTED

  3. Validate that the Old Credential is set to: GENERIC PRODUCT KEY SET DETECTED

  4. In the field New credential value, set: 1111111111111111111111111111111111111111111111111111111111111111 (64 repetitions of the digit 1)

  5. Hit the Apply button.

  6. Confirm the operation by hitting the OK button.

  7. Validate that the operation was successful and hit the OK button.

Step 1D: Container 05

  1. Select Container 05 and hit the Change Credential button.

  2. Validate that the Authentication Credential is set to: GENERIC PRODUCT KEY SET DETECTED

  3. Validate that the Old Credential is set to: GENERIC PRODUCT KEY SET DETECTED

  4. In the field New credential value, set: 1111111111111111111111111111111111111111111111111111111111111111 (64 repetitions of the digit 1)

  5. Hit the Apply button.

  6. Confirm the operation by hitting the OK button.

  7. Validate that the operation was successful and hit the OK button.

Step 1E: Container 07

  1. Select Container 07 and hit the Change Credential button.

  2. Validate that the Authentication Credential is set to: GENERIC PRODUCT KEY SET DETECTED

  3. Validate that the Old Credential is set to: GENERIC PRODUCT KEY SET DETECTED

  4. In the field New credential value, set: 1111111111111111111111111111111111111111111111111111111111111111 (64 repetitions of the digit 1)

  5. Hit the Apply button.

  6. Confirm the operation by hitting the OK button.

  7. Validate that the operation was successful and hit the OK button.

Step 2: Permanent CCID

  1. From the Token Administration menu select Settings.

  2. From the Token List select Smart Card.

  3. Hit the Select Interface button.

  4. Select the radio button CCID.

  5. Select the drop down menu selection Permanent.

  6. Hit the Apply button.

Validate that the operation was successful.

Step 3: Change Admin PIN

  1. From the Token Administration menu select Secure Storage.

  2. From the Token List Menu, select Admin PIN.

  3. Hit the Change Admin PIN button.

  4. In the field TMS Device Key enter: 1111111111111111111111111111111111111111111111111111111111111111 (64 repetitions of the digit 1)

  5. In the field New private partition Admin PIN enter: 12345678

  6. In the field Confirm private partition Admin PIN enter: 12345678

  7. Hit the Apply button.

  8. Confirm the operation by hitting the OK button.

  9. Validate that the operation was successful.

Step 4: Change PIN

  1. From the Token Administration menu select Secure Storage.

  2. From the Token List Menu, select PIN.

  3. Hit the Unblock PIN button.

  4. In the field Admin PIN enter: 12345678

  5. In the field New Private Partition PIN enter: 0000

  6. In the field Confirm Private Partition PIN enter: 0000

  7. Hit the Apply button.

  8. Confirm the operation by hitting the OK button.

  9. Validate that the operation was successful.

Step 5: Format Private Partition

  1. From the Token Administration menu select Secure Storage.

  2. From the Token List select Secure Storage.

  3. To the right of to the Open button there is an unnamed field, enter 0000 (the PIN) here.

  4. Hit the Open button.

  5. Confirm that private partion is open.

  6. Using your file browser, find the open private drive and format it to FAT32.

  7. When the formatting is completed, go back to the Toolbox and hit Lock

  8. Confirm that the drive is locked again.

  9. The Toolbox application can now be closed.